India, Nov. 5 -- INDIAN ARMY has issued a tender notice titled "Ml for Cable in Trenches or Passing through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip O, Qty: 6720" with the tender reference no.: GEM/2026/B/8220590.

The tender details are as follows: ML for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric1100 volts grade cross sectional area 10 sqmm 4 core , ML for cable in trenches or passing through pipe XLPE insulated heavy duty 1100 volts grade cross sectional area 25 sqmm 3.5 core , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth , Excavating in Trenches not exc. 1.50 mtr wide and exc. 1.50 mtr in depth , Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm , Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr , SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable , S F HDPE DWC Double Walled Corrugated of Diameter 40 mm with coupler including disconnection and connection of cable near panel OH , S F HDPE DWC Double Walled Corrugated of Diameter 63 mm , M L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia , ML for earthing complete with MS galvanized plate of size 60cm60cm6mm as earth electrode buried directly in ground earth pit not less than 2.25 1.5 mtrs , M L steel tubular swaged poles complete with cast iron base plate , Supply Fixing sheet moulding compound junction box IP 66 weather proof with double hinged door for outdoor installation of size 250 200 105 with knockouts for cable entry , Supply and fix 3 core flexible 1.5 sqmm copper multistranded cable from jun... Portland Slag Cement conforming to IS 455 BOQ Desc: ML for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed. Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. SF Galvanised Iron Pipe 50mm Bore dia for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. S F Double Walled Corrugated of Diameter 40 mm with coupler including disconnection and connection of cable near panel OH for pipe fixing including joints complete all as directed. S F HDPE DWC Double Walled Corrugated of Diameter 63 mm with including disconnection and connection of cable near panel OH for pipe fixing including joints complete all as directed. ML for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10.00 mtr in a Single Length complete all as specified and as directed. Note Pipe to be measured separately. ML for earthing complete with MS galvanized plate of size 60cm60cm6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip 25 4mm as earthing lead by means of bolts nuts check nuts and washers of galvanised iron welding or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earthing test point all as specified complete with excavation earth work PCC pit with 50mm thMS Rod 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor and testing on completion complete all as specified and as directed by Engineerin Charge. M L steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts screws as specified type 410 SP 31 9 metres long complete all as specified directed. Supply Fixing sheet moulding compound junction box IP 66 weather proof with double hinged door for outdoor installation of size 250 200 105 with knockouts for cable entry suitable for terminating 25 Sqmm UG cable including 2 or equivalent. Supply and fix 3 core flexible 1.5 sqmm copper multistranded cable from junction box to street light with connectors lugs thimble on both ends complete all as specified and directed. ML for Cement concrete in foundations filling and mass concrete type D2 148 using 40mm grade aggregate complete all as specified and as directed. ML for PCC 136 type C2 using 40mm grade aggregate as in foundation for pole etc complete all as specified and as directed. ML for PCC 124 type B1 using 20mm grade aggregate as in coping for pole inclduing form work and etc complete all as specified and directed. Supply and fix pressure die cast aluminiu...

The expression of interest should be received by Nov. 14.

For more information, contact INDIAN ARMY, Ministry of Defence|Department of Military Affairs Bardhaman 2100 90 ML For Cable In Trenches Or Passing Through Pipe XLPE Insulated Heavy, buyer2963.ia.wb@gembuyer.in.

Disclaimer: Curated by HT Syndication.